Al-Arif, Maan S. (2013) Unity Energy Response Using CaSO4:DY/Teflon. ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY, 1 (1). pp. 14-16. ISSN 2307-549X
Article_AROSJKY_11-11-2013.pdf - Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.
Download (492kB)
Abstract
energy response using the very sensitive CaSO4:Dy/Teflon thermoluminescent detector at photon energies below 100 keV. Accurate measurements for the energy responses were carried-out using ultra thin, 3 micron thick, TLD discs with average grain size of about 3μm. The present work shows that the experimental reduction factor for the 15 % phosphor loading with average grain size of 3 μm is in good agreement with the calculation based on the cavity theory but at grain size of 1.0 μm. This indicates that the cavity theory is underestimating the real experimental reduction factor in the energy response. The present work expect that unity energy response can be achieved with grain size of about 1 μm.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | Cavity Theory; Energy Response; Particle Size; Photon Energy; TLD discs. |
| Subjects: | Q Science > QA Mathematics Q Science > QC Physics Q Science > QD Chemistry |
| Divisions: | Department of Radiology and Imaging Technology > Research papers |
| Depositing User: | ePrints Depositor |
| Date Deposited: | 05 Aug 2025 06:25 |
| Last Modified: | 05 Aug 2025 06:25 |
| URI: | https://eprints.cihanuniversity.edu.iq/id/eprint/3884 |