Basem, Ali and Jasim, Dheyaa J. and Ghodratallah, Pooya and AbdulAmeer, S. and Mahmood, Ahmed Mohammed and Khudhayer, Wisam J. and Dabis, Hasan Khalid and Marefati, Mohammad (2024) Technical and Financial Feasibility of a Chemicals Recovery and Energy and Water Production From a Dairy Wastewater Treatment Plant. Scientific Reports, 14: 11143. ISSN 2045-2322
Article_SR_15-05-2024.pdf - Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.
Download (1MB)
Abstract
Due to the high volume of wastewater produced from dairy factories, it is necessary to integrate a water recovery process with the treatment plant. Today, bipolar membrane electrodialysis units (BMEUs) are increasingly developed for wastewater treatment and reutilizing. This article aims to develop and evaluate (technical and cost analyses) a combined BMEU/batch reverse osmosis unit (BROU) process for the recovery of chemicals and water from the dairy wastewater plant. The combined BROU/BMEU process is able to simultaneously produce water and strong base-acid, and reduce power consumption due to the injection of concentrated feed flow into the BMEU. A comprehensive comparative analysis on the performances of two combined and stand-alone BMEU configurations are developed. The proposed combined technology for dairy factory wastewater treatment is designed on a new structure and configuration that can address superior cost analysis compared to similar technologies. Further, the optimal values of permeate flux and current density as two vital and influencing parameters on the performance of the studied dairy wastewater treatment process were calculated and discussed. From the outcomes, the total cost of production in the combined configuration has been reduced by approximately 26% compared to the stand-alone configuration. Increasing the feed concentration rate using the batch reverse osmosis process for the dairy wastewater treatment process can be an ideal solution from an economic point of view. Moreover, point (current density, feed concentration rate, total unit cost) = $$\left(328.9, 7, 14.37\right)$$ 328.9 , 7 , 14.37 can be considered as an optimal point for the economic performance of the studied wastewater treatment process.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | Chemicals Recovery,Energy And Water Production, Dairy Wastewater Treatment Plant, Technical Assessment, Financial Feasibility, Permeate Water Fux |
| Subjects: | T Technology > TD Environmental technology. Sanitary engineering T Technology > TP Chemical technology |
| Divisions: | Department of Civil Engineering > Research papers |
| Depositing User: | ePrints Depositor |
| Date Deposited: | 20 Nov 2024 20:29 |
| Last Modified: | 20 Nov 2024 20:29 |
| URI: | https://eprints.cihanuniversity.edu.iq/id/eprint/3016 |