Sultan, Abbas J. and Sabri, Laith S. and Al-Dahhan, Muthanna H. (2018) Investigating the Influence of the Configuration of The Bundle of Heat Exchanging Tubes and Column Size on the Gas Holdup Distributions in Bubble Columns Via Gamma-Ray Computed Tomography. Experimental Thermal and Fluid Science, 98. pp. 68-85. ISSN 08941777
Article_ETFS_11-05-2018.pdf - Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.
Download (79kB)
Abstract
The impact of dense vertical internal tubes and their configurations on the gas holdup distributions and their diametrical profiles in pilot-scale bubble column is visualized and quantified for the first time ever using an advanced gamma-ray computed tomography (CT) technique. Two arrangements of vertical internals (circular and hexagonal configurations) occupying the same cross-sectional area (CSA) of the column (about 25% of the total cross-sectional area to represent the heat exchanging tubes that are used in the Fischer-Tropsch synthesis), were examined in addition to the measurement in the bubble column without vertical internals. Moreover, the gas holdup distribution results of the 18-inch (0.46 m in outer diameter, O.D.) bubble column are compared with an available data of 6-inch (0.15 m in O.D.) bubble columns with and without vertical internals. CT scans have been conducted for 18-inch bubble columns with and without vertical internals for the air-water system under a wide range of superficial gas velocity (0.05–0.45 m/s). The experimental results indicate that an improvement in the gas holdup distribution over the column's cross-sectional area is obtained when the vertical internal tubes (arranged in either a circular or a hexagonal configuration) were used. However, better cross-sectional gas holdup distribution was achieved in the bubble column with vertical internals arranged in a hexagonal configuration as compared to the bubble column without and with vertical internals arranged in a circular arrangement. Additionally, the averages of the cross-sectional gas holdup and their profiles for bubble column with and without vertical internals are close to each other when the bubble column with vertical internals is operating at a high superficial gas velocity, which is calculated based on the free cross-sectional area for the flow. Furthermore, the gas holdup distributions are further improved when the larger bubble column with vertical internals was used as compared to the 6-inch bubble columns with and without vertical internals.
| Item Type: | Article |
|---|---|
| Uncontrolled Keywords: | Computed Tomography (CT), Configurations of Vertical Internals, Gas Holdup Distribution, Pilot-Scale Bubble Column, Vertical Internal Tubes |
| Subjects: | Q Science > QD Chemistry Q Science > QR Microbiology R Medicine > R Medicine (General) |
| Divisions: | Department of Medical Biochemical Analysis > Research papers |
| Depositing User: | ePrints Depositor |
| Date Deposited: | 26 Sep 2024 12:01 |
| Last Modified: | 26 Sep 2024 12:01 |
| URI: | https://eprints.cihanuniversity.edu.iq/id/eprint/215 |